X-Mozilla-Status: 0000 X-Mozilla-Status2: 00000000 Received: from iw8.persiantools.net ([185.129.169.244]) by dnswebhost.com with MailEnable ESMTP; Wed, 26 Oct 2022 14:55:46 +0330 Received: from D0303 ([178.248.40.178]) by iw8.persiantools.net with MailEnable ESMTPA; Wed, 26 Oct 2022 14:55:45 +0330 From: "MD" To: References: <000b01d8e85e$7fcd23f0$7f676bd0$@resmship.com> In-Reply-To: <000b01d8e85e$7fcd23f0$7f676bd0$@resmship.com> Subject: FW: MT Eastern Pride : BV Surveyor comments on 25 Oct. 2022 Date: Wed, 26 Oct 2022 14:54:19 +0330 Message-ID: <009d01d8e92d$7dc2d3f0$79487bd0$@daryaban.com> MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_009E_01D8E94A.D3F3C690" X-Mailer: Microsoft Outlook 14.0 Thread-Index: AQEjUmnfcAqjZobAIueLosJrLp2dJAFwwbOir4Av22A= Content-Language: en-us Return-Path: This is a multipart message in MIME format. ------=_NextPart_000_009E_01D8E94A.D3F3C690 Content-Type: text/plain; charset="UTF-8" Content-Transfer-Encoding: quoted-printable Good day, =20 pls find survwyor=E2=80=99s comments. =20 Thanks! Best Regards, =20 =20 Subject: =E7=AD=94=E5=A4=8D: Re : comments on 25 Oct. 2022 =20 Dear Sir, The general inspection was carried out on main deck and comments as = following: -Hatchway to cargo hold No.1 to No.6 and slop tank P/S found small cover = and coaming corroded/wasted, need chipping to confirm condition. -Man holes of cargo hold No.1 to No.6 found cover plating and coaming = top plating corroded/wasted, need chipping to confirm condition.(some = need repair and already marked) -Hatchway of No.1 to No.6 B.W.T. P/S found internal structure = corroded/wasted, need repair. -If steam line on deck are not used, need blinding and issue MO, please = confirm. -Gravity valves of ballast tanks on main deck found supporting corroded, = need repair. -All the valves on deck need maintenance to confirm condition. -Control valves of foam guns need maintenance. -Some piping and valves found corroded/wasted which already marked, need = repair. -Mooring winches P/S found some parts corroded/wasted and some hydraulic = piping leaking which already marked, need repair. -Skylight to pump room found cover and coaming corroded/wasted which = already marked, need repair. -The weather tight doors to pump room and deck house found coaming = corroded/wasted which already marked, need repair. -Lover ventilator to deck house found coaming corroded/wasted which = already marked, need repair. -Emergency stop box to deck house found holed which already marked, need = repair. -Lamp near pump room port found foundation corroded/wasted which already = marked, need repair. -Soft ladder port need replace. -Foundation of soft ladder P/S found corroded which already marked, need = repair. -Ladder P/S found launching devices corroded which already marked, need = repair. -Windlass port found connection shaft malfunction, need repair. -Chain stopper P/S found handle deformed, need repair. -Some hydraulic piping found corroded, need repair. -Fore small hatch cover found coaming corroded, need repair. -Mooring line hole found cover coaming corroded, need repair. -Fire hose box on fore deck found corroded, need repair. -Anchor chain P/S found below limit, need replace with BV certificate. -Sounding pipe near pump room Std. found corroded, need repair. Thank you. Best regards ------=_NextPart_000_009E_01D8E94A.D3F3C690 Content-Type: text/html; charset="UTF-8" Content-Transfer-Encoding: quoted-printable

Good day,

 

pls find survwyor=E2=80=99s = comments.

 

Thanks!

Best Regards,

 

 

Subject: = =E7=AD=94=E5=A4=8D: Re : = comments on 25 Oct. 2022

 

Dear Sir,

The general = inspection was carried out on main deck and comments as = following:

-Hatchway to cargo hold = No.1 to No.6 and slop tank P/S found small cover and coaming = corroded/wasted, need chipping to confirm condition.

-Man holes of cargo hold No.1 to No.6 found cover = plating and coaming top plating corroded/wasted, need chipping to = confirm condition.(some need repair and already marked)

-Hatchway of No.1 to No.6 B.W.T. P/S found internal = structure corroded/wasted, need repair.

-If steam line on deck are not used, need blinding and = issue MO, please confirm.

-Gravity = valves of ballast tanks on main deck found supporting corroded, need = repair.

-All the valves on deck need = maintenance to confirm condition.

-Control valves of foam guns need = maintenance.

-Some piping and valves = found corroded/wasted which already marked, need = repair.

-Mooring winches P/S found = some parts corroded/wasted and some hydraulic piping leaking which = already marked, need repair.

-Skylight to pump room found cover and coaming = corroded/wasted which already marked, need repair.

-The weather tight doors to pump room and deck house = found coaming corroded/wasted which already marked, need = repair.

-Lover ventilator to deck = house found coaming corroded/wasted which already marked, need = repair.

-Emergency stop box to deck = house found holed which already marked, need repair.

-Lamp near pump room port found foundation = corroded/wasted which already marked, need repair.

-Soft ladder port need replace.

-Foundation of soft ladder P/S found corroded which = already marked, need repair.

-Ladder = P/S found launching devices corroded which already marked, need = repair.

-Windlass port found = connection shaft malfunction, need repair.

-Chain stopper P/S found handle deformed, need = repair.

-Some hydraulic piping found = corroded, need repair.

-Fore small = hatch cover found coaming corroded, need repair.

-Mooring line hole found cover coaming corroded, need = repair.

-Fire hose box on fore deck = found corroded, need repair.

-Anchor = chain P/S found below limit, need replace with BV = certificate.

-Sounding pipe near pump = room Std. found corroded, need repair.