X-Mozilla-Status: 0000 X-Mozilla-Status2: 00000000 Received: from iw8.persiantools.net ([185.129.169.244]) by dnswebhost.com with MailEnable ESMTP; Wed, 26 Oct 2022 14:53:45 +0330 Received: from D0303 ([178.248.40.178]) by iw8.persiantools.net with MailEnable ESMTPA; Wed, 26 Oct 2022 14:53:45 +0330 From: "MD" To: References: <000d01d8e7b7$a0b81680$e2284380$@resmship.com> In-Reply-To: <000d01d8e7b7$a0b81680$e2284380$@resmship.com> Subject: FW: Re : comments on 24 Oct. 2022 Date: Wed, 26 Oct 2022 14:52:19 +0330 Message-ID: <009001d8e92d$36494040$a2dbc0c0$@daryaban.com> MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0091_01D8E94A.8C7D4020" X-Mailer: Microsoft Outlook 14.0 Thread-Index: AQGIaP01DcEjLzQBJzstsrm12POynQJAL8cgrq+GmMA= Content-Language: en-us Return-Path: X-Read: 1 This is a multipart message in MIME format. ------=_NextPart_000_0091_01D8E94A.8C7D4020 Content-Type: text/plain; charset="UTF-8" Content-Transfer-Encoding: quoted-printable Good day, =20 pls find comments on requiremets.=20 =20 Thanks! Best Regards, =20 -------------------------------------------------------------------------= ------------------------------------------------ Subject: =E7=AD=94=E5=A4=8D: Re : comments on 24 Oct. 2022 =20 Dear Sir, The general inspection was carried out on poop deck and accommodation = area, comments as following: -Additional two sets of LL marks need add. -D shackle to anchor P/S and connected swivel chain found corrosion = beyond limit, need replace. -Mooring winch P/S on poop deck found hydraulic piping corroded/leaking = and flat bar of collection oil box corroded, need repair. - Mooring winch S on poop deck found brake liner connection bar broken, = need repair. -Mushroom type of ventilator after for steering gear room found junction = box broken and internal structure corroded, need repair. -Fire hydrant box No.13 found supporting structure corroded, need = repair. -Light on poop deck port found supporting structure corroded, need = repair. -Light on poop deck above acetylene room found supporting structure = corroded, need repair. -NAT lover found cover coaming corroded, need repair. -The hatchway for rope found cover coaming corroded, need repair. -The small hatchway to steering gear room found cover coaming/locking = devices corroded, need repair. -Pillar for E.T.D. found brackets corroded, need repair. -Stern signal light found foundation corroded, need repair. -The pipe for E.T.D steel line found corroded, need repair. -E.T.A. box found holed, need repair. -Acetylene and oxygen room found door bulkhead corroded, need repair. -Lover ventilator for deck workshop found mesh corroded, need repair. -Oil collection boxes on accommodation area found coaming corroded, need = repair. -Lover ventilator for central store found mesh and cover corroded, need = repair. -International connection port found supporting bar corroded, need = repair. -3S VLSFO tank found brackets and drain pipe corroded, need repair. -Liferafts P/S found supporting structure wasted, need repair. -Soft ladder P/S found deteriorated, need replace. -Cable pipe of lifeboat Std. found corroded, need repair. -Signal light P/S found opening door corroded, need repair. -No.2 and No.3 VLSFO STD found valve corroded, need chipping to confirm = the condition. -Lover ventilator for drying Hmbler found cover coaming corroded, need = repair. -Fire valves with hand wheels on accommodation area need maintenance. -Fire control plan STD. in collection pipe found broken, need replace. -Lover ventilator for garbage store found cover coaming corroded, need = repair. - Lover ventilator for dry provison store found cover coaming corroded, = need repair.=EF=BC=88three pieces=EF=BC=89 - Lover ventilator for galley found cover coaming corroded, need = repair.(two pieces) - Lover ventilator for A/C room found cover coaming and casing coaming = corroded, need repair. - Lover ventilator for galley F.C.O. found cover coaming and casing = coaming corroded, need repair. - Fire hydrant box No.12 found supporting structure corroded, need = repair. - Lover ventilator for GYM found cover coaming and casing coaming = corroded, need repair. -Fan and light of paint store found box door sealing rubber lost, need = repair. -Fire line to paint locker found corroded, need repair. - Lover ventilator for paint store found cover coaming corroded, need = repair. -Sounding pipe of L.O. store tank found holed, need repair. -Emergency stop box port found corroded, need repair. -Feed filter tank found vent pipe coiled by cement, need repair. -The door of E/G room found lower coaming corroded, need repair. -The connection pipe of GEN oil, M.E. oil, CYL. Oil, Sewage need = replace. -Cable penetration of emergency light port above boat deck found holed, = need repair. -No.2 and No.3 VLSFO tank overfill sensor found cable piping corroded, = need repair. -Emergency alarm box found supporting structure corroded, need repair. -Ventilator for pump room found junction box and casing corroded, need = repair. -One pipe collection box near ventilator of pump room on inert gas line = found corroded, need repair. -Mechanical vent in accommodation deck found cover coaming corroded, = need repair. -Lift trunk found lover casing lower part corroded, need repair. -The cable penetration near battery room found corroded, need repair. -The door of battery room found lower coaming corroded, need repair. - Lover ventilator for locker on wheel house std. found cover coaming = corroded, need repair. - Lover ventilator for ELEC equipment store on wheel house std. found = cover coaming corroded, need repair. - Lover ventilator for wheel chart space found cover coaming corroded, = need repair. -Fire pipe on wheel house std. found holed, need replace. -cable supporting bars on wheel house std. found corroded, need replace. -Ventilator on monkey island found corroded, need repair. -Bell supporting on monkey island found corroded, need repair. - Lover ventilator for drying tumbler found cover coaming corroded, need = repair. -Speaker foundation found corroded, need repair. -Ventilator for emergency generator room found internal structure = corroded, need repair. -Air vents near Ventilator for emergency generator room found side cover = corroded, need repair. -Mushroom ventilator for paint store found cap casing corroded, need = repair. - cable penetration near Mushroom ventilator for paint store found = corroded, need repair. -Ventilators of E/R found lower coaming flange corroded, need repair. -The door near Ventilator of E/R found lower coaming corroded, need = repair. -The closing plate and pipe end found of inert gas fresh air intake = found corroded, need repair. -Deck workshop vent, garbage vent and central locker found cable = junction box and internal structure corroded, need repair. =20 Thank you. Best regards ------=_NextPart_000_0091_01D8E94A.8C7D4020 Content-Type: text/html; charset="UTF-8" Content-Transfer-Encoding: quoted-printable

Good day,

 

pls find comments on requiremets. =

 

Thanks!

Best Regards,

 

----------------------------------------------------------------------= ---------------------------------------------------=

Subject: = =E7=AD=94=E5=A4=8D: Re : = comments on 24 Oct. 2022

 

Dear = Sir,

The general inspection was = carried out on poop deck and accommodation area, comments as = following:

-Additional two sets of LL marks need = add.

-D shackle to anchor P/S and = connected swivel chain found corrosion beyond limit, need = replace.

-Mooring winch P/S on poop = deck found hydraulic piping corroded/leaking and flat bar of collection = oil box corroded, need repair.

- = Mooring winch S on poop deck found brake liner connection bar broken, = need repair.

-Mushroom type of = ventilator after for steering gear room found junction box broken and = internal structure corroded, need repair.

-Fire hydrant box No.13 found supporting structure = corroded, need repair.

-Light on poop = deck port found supporting structure corroded, need = repair.

-Light on poop deck above = acetylene room found supporting structure corroded, need = repair.

-NAT lover found cover = coaming corroded, need repair.

-The = hatchway for rope found cover coaming corroded, need = repair.

-The small hatchway to = steering gear room found cover coaming/locking devices corroded, need = repair.

-Pillar for E.T.D. found = brackets corroded, need repair.

-Stern signal light found foundation corroded, need = repair.

-The pipe for E.T.D steel = line found corroded, need repair.

-E.T.A. box found holed, need repair.

-Acetylene and oxygen room found door bulkhead = corroded, need repair.

-Lover = ventilator for deck workshop found mesh corroded, need = repair.

-Oil collection boxes on = accommodation area found coaming corroded, need repair.

-Lover ventilator for central store found mesh and = cover corroded, need repair.

-International connection port found supporting bar = corroded, need repair.

-3S VLSFO tank = found brackets and drain pipe corroded, need repair.

-Liferafts P/S found supporting structure wasted, need = repair.

-Soft ladder P/S found = deteriorated, need replace.

-Cable = pipe of lifeboat Std. found corroded, need repair.

-Signal light P/S found opening door corroded, need = repair.

-No.2 and No.3 VLSFO STD = found valve corroded, need chipping to confirm the = condition.

-Lover ventilator for = drying Hmbler found cover coaming corroded, need = repair.

-Fire valves with hand wheels = on accommodation area need maintenance.

-Fire control plan STD. in collection pipe found = broken, need replace.

-Lover = ventilator for garbage store found cover coaming corroded, need = repair.

- Lover ventilator for dry = provison store found cover coaming corroded, need repair.=EF=BC=88t= hree pieces=EF=BC=89<= o:p>

- Lover ventilator for galley found = cover coaming corroded, need repair.(two pieces)

- Lover ventilator for A/C room found cover coaming = and casing coaming corroded, need repair.

- Lover ventilator for galley F.C.O. found cover = coaming and casing coaming corroded, need repair.

- Fire hydrant box No.12 found supporting structure = corroded, need repair.

- Lover = ventilator for GYM found cover coaming and casing coaming corroded, need = repair.

-Fan and light of paint store = found box door sealing rubber lost, need repair.

-Fire line to paint locker found corroded, need = repair.

- Lover ventilator for paint = store found cover coaming corroded, need repair.

-Sounding pipe of L.O. store tank found holed, need = repair.

-Emergency stop box port = found corroded, need repair.

-Feed = filter tank found vent pipe coiled by cement, need = repair.

-The door of E/G room found = lower coaming corroded, need repair.

-The connection pipe of GEN oil, M.E. oil, CYL. Oil, = Sewage need replace.

-Cable = penetration of emergency light port above boat deck found holed, need = repair.

-No.2 and No.3 VLSFO tank = overfill sensor found cable piping corroded, need = repair.

-Emergency alarm box found = supporting structure corroded, need repair.

-Ventilator for pump room found junction box and = casing corroded, need repair.

-One = pipe collection box near ventilator of pump room on inert gas line found = corroded, need repair.

-Mechanical = vent in accommodation deck found cover coaming corroded, need = repair.

-Lift trunk found lover = casing lower part corroded, need repair.

-The cable penetration near battery room found = corroded, need repair.

-The door of = battery room found lower coaming corroded, need repair.

- Lover ventilator for locker on wheel house std. = found cover coaming corroded, need repair.

- Lover ventilator for ELEC equipment store on wheel = house std. found cover coaming corroded, need repair.

- Lover ventilator for wheel chart space found cover = coaming corroded, need repair.

-Fire = pipe on wheel house std. found holed, need replace.

-cable supporting bars on wheel house std. found = corroded, need replace.

-Ventilator = on monkey island found corroded, need repair.

-Bell supporting on monkey island found corroded, need = repair.

- Lover ventilator for drying = tumbler found cover coaming corroded, need repair.

-Speaker foundation found corroded, need = repair.

-Ventilator for emergency = generator room found internal structure corroded, need = repair.

-Air vents near Ventilator = for emergency generator room found side cover corroded, need = repair.

-Mushroom ventilator for = paint store found cap casing corroded, need repair.

- cable penetration near Mushroom ventilator for paint = store found corroded, need repair.

-Ventilators of E/R found lower coaming flange = corroded, need repair.

-The door near = Ventilator of E/R found lower coaming corroded, need = repair.

-The closing plate and pipe = end found of inert gas fresh air intake found corroded, need = repair.

-Deck workshop vent, garbage = vent and central locker found cable junction box and internal structure = corroded, need repair.

 

Thank = you.