Subject: FW: MT Eastern Pride : BV Surveyor comments on 25 Oct. 2022 From: "MD" Date: 26/10/2022, 04:24 To: Good day, pls find survwyor’s comments. Thanks! Best Regards, Subject: 答复: Re : comments on 25 Oct. 2022 Dear Sir, The general inspection was carried out on main deck and comments as following: -Hatchway to cargo hold No.1 to No.6 and slop tank P/S found small cover and coaming corroded/wasted, need chipping to confirm condition. -Man holes of cargo hold No.1 to No.6 found cover plating and coaming top plating corroded/wasted, need chipping to confirm condition.(some need repair and already marked) -Hatchway of No.1 to No.6 B.W.T. P/S found internal structure corroded/wasted, need repair. -If steam line on deck are not used, need blinding and issue MO, please confirm. -Gravity valves of ballast tanks on main deck found supporting corroded, need repair. -All the valves on deck need maintenance to confirm condition. -Control valves of foam guns need maintenance. -Some piping and valves found corroded/wasted which already marked, need repair. -Mooring winches P/S found some parts corroded/wasted and some hydraulic piping leaking which already marked, need repair. -Skylight to pump room found cover and coaming corroded/wasted which already marked, need repair. -The weather tight doors to pump room and deck house found coaming corroded/wasted which already marked, need repair. -Lover ventilator to deck house found coaming corroded/wasted which already marked, need repair. -Emergency stop box to deck house found holed which already marked, need repair. -Lamp near pump room port found foundation corroded/wasted which already marked, need repair. -Soft ladder port need replace. -Foundation of soft ladder P/S found corroded which already marked, need repair. -Ladder P/S found launching devices corroded which already marked, need repair. -Windlass port found connection shaft malfunction, need repair. -Chain stopper P/S found handle deformed, need repair. -Some hydraulic piping found corroded, need repair. -Fore small hatch cover found coaming corroded, need repair. -Mooring line hole found cover coaming corroded, need repair. -Fire hose box on fore deck found corroded, need repair. -Anchor chain P/S found below limit, need replace with BV certificate. -Sounding pipe near pump room Std. found corroded, need repair. Thank you. Best regards