Subject: FW: Re : comments on 24 Oct. 2022 From: "MD" Date: 26/10/2022, 04:22 To: Good day, pls find comments on requiremets. Thanks! Best Regards, ------------------------------------------------------------------------------------------------------------------------- Subject: 答复: Re : comments on 24 Oct. 2022 Dear Sir, The general inspection was carried out on poop deck and accommodation area, comments as following: -Additional two sets of LL marks need add. -D shackle to anchor P/S and connected swivel chain found corrosion beyond limit, need replace. -Mooring winch P/S on poop deck found hydraulic piping corroded/leaking and flat bar of collection oil box corroded, need repair. - Mooring winch S on poop deck found brake liner connection bar broken, need repair. -Mushroom type of ventilator after for steering gear room found junction box broken and internal structure corroded, need repair. -Fire hydrant box No.13 found supporting structure corroded, need repair. -Light on poop deck port found supporting structure corroded, need repair. -Light on poop deck above acetylene room found supporting structure corroded, need repair. -NAT lover found cover coaming corroded, need repair. -The hatchway for rope found cover coaming corroded, need repair. -The small hatchway to steering gear room found cover coaming/locking devices corroded, need repair. -Pillar for E.T.D. found brackets corroded, need repair. -Stern signal light found foundation corroded, need repair. -The pipe for E.T.D steel line found corroded, need repair. -E.T.A. box found holed, need repair. -Acetylene and oxygen room found door bulkhead corroded, need repair. -Lover ventilator for deck workshop found mesh corroded, need repair. -Oil collection boxes on accommodation area found coaming corroded, need repair. -Lover ventilator for central store found mesh and cover corroded, need repair. -International connection port found supporting bar corroded, need repair. -3S VLSFO tank found brackets and drain pipe corroded, need repair. -Liferafts P/S found supporting structure wasted, need repair. -Soft ladder P/S found deteriorated, need replace. -Cable pipe of lifeboat Std. found corroded, need repair. -Signal light P/S found opening door corroded, need repair. -No.2 and No.3 VLSFO STD found valve corroded, need chipping to confirm the condition. -Lover ventilator for drying Hmbler found cover coaming corroded, need repair. -Fire valves with hand wheels on accommodation area need maintenance. -Fire control plan STD. in collection pipe found broken, need replace. -Lover ventilator for garbage store found cover coaming corroded, need repair. - Lover ventilator for dry provison store found cover coaming corroded, need repair.(three pieces) - Lover ventilator for galley found cover coaming corroded, need repair.(two pieces) - Lover ventilator for A/C room found cover coaming and casing coaming corroded, need repair. - Lover ventilator for galley F.C.O. found cover coaming and casing coaming corroded, need repair. - Fire hydrant box No.12 found supporting structure corroded, need repair. - Lover ventilator for GYM found cover coaming and casing coaming corroded, need repair. -Fan and light of paint store found box door sealing rubber lost, need repair. -Fire line to paint locker found corroded, need repair. - Lover ventilator for paint store found cover coaming corroded, need repair. -Sounding pipe of L.O. store tank found holed, need repair. -Emergency stop box port found corroded, need repair. -Feed filter tank found vent pipe coiled by cement, need repair. -The door of E/G room found lower coaming corroded, need repair. -The connection pipe of GEN oil, M.E. oil, CYL. Oil, Sewage need replace. -Cable penetration of emergency light port above boat deck found holed, need repair. -No.2 and No.3 VLSFO tank overfill sensor found cable piping corroded, need repair. -Emergency alarm box found supporting structure corroded, need repair. -Ventilator for pump room found junction box and casing corroded, need repair. -One pipe collection box near ventilator of pump room on inert gas line found corroded, need repair. -Mechanical vent in accommodation deck found cover coaming corroded, need repair. -Lift trunk found lover casing lower part corroded, need repair. -The cable penetration near battery room found corroded, need repair. -The door of battery room found lower coaming corroded, need repair. - Lover ventilator for locker on wheel house std. found cover coaming corroded, need repair. - Lover ventilator for ELEC equipment store on wheel house std. found cover coaming corroded, need repair. - Lover ventilator for wheel chart space found cover coaming corroded, need repair. -Fire pipe on wheel house std. found holed, need replace. -cable supporting bars on wheel house std. found corroded, need replace. -Ventilator on monkey island found corroded, need repair. -Bell supporting on monkey island found corroded, need repair. - Lover ventilator for drying tumbler found cover coaming corroded, need repair. -Speaker foundation found corroded, need repair. -Ventilator for emergency generator room found internal structure corroded, need repair. -Air vents near Ventilator for emergency generator room found side cover corroded, need repair. -Mushroom ventilator for paint store found cap casing corroded, need repair. - cable penetration near Mushroom ventilator for paint store found corroded, need repair. -Ventilators of E/R found lower coaming flange corroded, need repair. -The door near Ventilator of E/R found lower coaming corroded, need repair. -The closing plate and pipe end found of inert gas fresh air intake found corroded, need repair. -Deck workshop vent, garbage vent and central locker found cable junction box and internal structure corroded, need repair. Thank you. Best regards